Property Address:
1234 Inspector Dr.
Somewhere, FL 39999
![]() |
| Date: 3/21/2006 | Time: 1:48 PM | Report ID: |
| Property: 1234 Inspector Dr. Somewhere, FL 39999 |
Customer: Jon Doe |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 10 Years | Client Is Present: Yes | Radon Test: No |
| Water Test: No | Weather: Clear | Temperature: Over 65 |
| Rain in last 3 days: No |
| Roof Covering: Asphalt/Fiberglass | Viewed roof covering from: Ground Ladder Extra Info : Windows | Sky Light(s): None |
| Chimney (exterior): N/A |
| 1.0 | ROOF COVERINGS Comments: Repair or Replace The Roof shingles has been repaired at the ridge. I am unable to determine if this repair will leak or fail. A qualified contractor should inspect and repair as needed.
Loose Granules could indicate that a shingle roof covering is nearing the end of it's useful life. A qualified contractor should repair or replace as needed.
|
| 1.1 | FLASHINGS Comments: Repair or Replace Flashing may have failed above half bath. There is evidence of a past or present leak on ceiling of half bath. Siding has deteriorated and will continue to if not repaired or replaced. A qualified contractor should inspect and repair as necessary.
|
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Inspected The plumbing vent pipe and exhaust fan vent need resealing around the perimeter of pipe and boot where boot flange has failed.
|
| 1.3 | ROOF DRAINAGE SYSTEMS Comments: Inspected |
![]() |
![]() |
![]() |
| Siding Style: Lap | Siding Material: Cement-Fiber Composite board | Exterior Entry Doors: Wood |
| Appurtenance: Deck with steps Balcony Porch Sidewalk Deck | Driveway: Concrete |
| 2.0 | WALL CLADDING FLASHING AND TRIM Comments: Repair or Replace The Composite board siding at the front of home and rear of home is deteriorated. Further deterioration can occur if not corrected. A qualified person should repair or replace as needed.
|
| 2.1 | DOORS (Exterior) Comments: Inspected |
| 2.2 | WINDOWS Comments: Inspected |
| 2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Comments: Repair or Replace The floor joist(s) and decking on the deck at the rear of home (Picture 1) and right side (A/C platform) (Picture 2) appear to be water damaged and has mold/mildew. Further deterioration can occur if not repaired. I recommend monitor and repair if needed.
|
| 2.4 | VEGETATION, GRADING,
DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With
respect to their effect on the condition of the building) Comments: Inspected |
| 2.5 | EAVES, SOFFITS AND FASCIAS Comments: Repair or Replace The wood fascia at eave on the front, the right side (facing front) and left side (facing front) are deteriorated. Further deterioration may occur if not repaired. A qualified person should repair or replace as needed.
The soffit panel at eave on the rear of home is missing. Deterioration may occur if not corrected. A qualified person should repair or replace as needed.
|
| Garage Door Type: Two automatic | Garage Door Material: Metal | Auto-opener Manufacturer: GENIE |
| 3.0 | GARAGE CEILINGS Comments: Inspected |
| 3.1 | GARAGE WALLS (INCLUDING FIREWALL SEPARATION) Comments: Inspected |
| 3.2 | GARAGE FLOOR Comments: Inspected |
| 3.3 | GARAGE DOOR (S) Comments: Inspected |
| 3.4 | OCCUPANT DOOR FROM GARAGE TO INSIDE HOME Comments: Inspected |
| 3.5 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Comments: Inspected |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Ceiling Materials: Sheetrock Plaster | Wall Material: Sheetrock Plaster | Floor Covering(s): Carpet Tile Wood |
| Interior Doors: Solid Raised panel Wood | Window Types: Single-hung Casement Sliders | Window Manufacturer: UNKNOWN |
| Cabinetry: Wood | Countertop: Corian |
| 4.0 | CEILINGS Comments: Inspected |
| 4.1 | WALLS Comments: Inspected |
| 4.2 | FLOORS Comments: Inspected |
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected |
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected |
| 4.5 | DOORS (REPRESENTATIVE NUMBER) Comments: Repair or Replace The Shower door missing knob hardware at the Master bath. This is a small repair. A qualified person should repair or replace as needed.
The Entry door is missing a strike-plate and dead-bolt plate on jamb at the garage. This is a small repair. A qualified person should repair or replace as needed.
The Sliding screen door is damaged at the workshop. This is a maintenance issue and is for your information. I recommend repair as desired.
|
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments: Repair or Replace One window difficult to operate at the office. A repair may be needed. A qualified person should repair or replace as needed.
One window is damaged at handle or lock hardware at the Dining Room. A repair may be needed. A qualified person should repair or replace as needed.
|
| Foundation: Poured concrete | Method used to observe Crawlspace: No crawlspace | Floor Structure: Engineered floor joists |
| Wall Structure: 2 X 4 Wood | Ceiling Structure: 2X4 | Roof Structure: Engineered wood trusses 2 X 4 Rafters |
| Roof-Type: Gable Hip | Method used to observe attic: From entry | Attic info: Attic access Light in attic |
| 5.0 | FOUNDATIONS, BASEMENTS
AND CRAWLSPACES (Report signs of abnormal or harmful water penetration
into the building or signs of abnormal or harmful condensation on
building components.) Comments: Inspected |
| 5.1 | WALLS (Structural) Comments: Inspected |
| 5.2 | COLUMNS OR PIERS Comments: Inspected |
| 5.3 | FLOORS (Structural) Comments: Inspected |
| 5.4 | CEILINGS (structural) Comments: Inspected |
| 5.5 | ROOF STRUCTURE AND ATTIC Comments: Repair or Replace The roof sheathing is deteriorated under soffit. Area still remains strong. It is not cost effective to replace until next roof. A qualified contractor should repair as needed.
|
![]() |
![]() |
| Water Source: Public | Water Filters: Whole house conditioner | Plumbing Water Supply (into home): Copper |
| Plumbing Water Distribution (inside home): Copper | Washer Drain Size: Not visible | Plumbing Waste: PVC |
| Water Heater Power Source: Electric | Water Heater Capacity: 50 Gallon (2-3 people) | Manufacturer: RHEEM |
| 6.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS Comments: Repair or Replace The plumbing waste line leaks at the Half Bath sink. Repairs are needed. A qualified licensed plumber should repair or correct as needed.
The tub drain overflow is upside down in the hall bath. Repairs are needed. A qualified person should repair as necessary.
|
| 6.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Repair or Replace The cold supply line has a corroded joint at connection in the garage. A licensed plumber should troubleshoot further to determine cause or remedy.
The tub faucet and tub spout are loose in wall and also need caulking at the hall bath. Repairs are needed. A qualified licensed plumber should repair or correct as needed.
The toilet stop-valve hose connection has a possible leak or has leaked in the past at the hall bath. A qualified licensed plumber should inspect and repair, if needed. A licensed plumber should troubleshoot further to determine cause or remedy.
The cold control tub faucet leaks at the downstairs bath. Repairs are needed. A qualified licensed plumber should repair or correct as needed.
|
| 6.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected |
| 6.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected The main shut off is located outside in the ground. Another shut off is the blue knob located in the workshop under shelving. This is for your information.
|
| 6.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments: Inspected |
| 6.5 | MAIN FUEL SHUT OFF (Describe Location) Comments: Inspected The main fuel shut off is at gas meter outside
|
| 6.6 | SUMP PUMP Comments: Not Present |
| Electrical Service Conductors: 220 volts | Panel capacity: 200 AMP | Panel Type: Circuit breakers |
| Electric Panel Manufacturer: SQUARE D | Branch wire 15 and 20 AMP: Copper | Wiring Methods: Romex |
| 7.0 | SERVICE ENTRANCE CONDUCTORS Comments: Inspected |
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Repair or Replace The main panel has one circuit breaker that appears to be popped out. A qualified electrician should repair or replace.
|
| 7.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected |
| 7.3 | CONNECTED DEVICES AND
FIXTURES (Observed from a representative number operation of ceiling
fans, lighting fixtures, switches and receptacles located inside the
house, garage, and on the dwelling's exterior walls) Comments: Inspected |
| 7.4 | POLARITY AND GROUNDING
OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL
RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected |
| 7.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected |
| 7.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments: Inspected The main panel box is located at the laundry room.
|
| 7.7 | SMOKE DETECTORS Comments: Inspected |
![]() |
| Heat Type: Forced Air Electric heat | Energy Source: Electric | Number of Heat Systems (excluding wood): Two |
| Heat System Brand: AMERICAN STANDARD TRANE | Ductwork: Insulated | Filter Type: Disposable |
| Filter Size: 18x18 18x24 | Types of Fireplaces: None | Operable Fireplaces: None |
| Number of Woodstoves: None | Cooling Equipment Type: Air conditioner unit | Cooling Equipment Energy Source: Electricity |
| Central Air Manufacturer: TRANE | Number of AC Only Units: Two |
| 8.0 | HEATING EQUIPMENT Comments: Inspected |
| 8.1 | NORMAL OPERATING CONTROLS Comments: Inspected |
| 8.2 | AUTOMATIC SAFETY CONTROLS Comments: Inspected |
| 8.3 | DISTRIBUTION SYSTEMS
(including fans, pumps, ducts and piping, with supports, insulation,
air filters, registers, radiators, fan coil units and convectors) Comments: Inspected |
| 8.4 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected |
| 8.5 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Comments: Not Present |
| 8.6 | SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) Comments: Not Present |
| 8.7 | GAS/LP FIRELOGS AND FIREPLACES Comments: Not Present |
| 8.8 | COOLING AND AIR HANDLER EQUIPMENT Comments: Repair or Replace The air handler is deteriorated. A more thorough inspection by a qualified contractor is needed. A licensed HVAC contractor should service or repair unit.
The standard running temperature difference between the return air and the cooled air should be approximately 20 degrees Fahrenheit. The second floor system had a return air temperature of 73 degrees and a cooled air temperature of 64 degrees. The first floor system had a return air temperature of 78 degrees and a cooled air temperature of 60 degrees. The second floor system may need further inspection by a qualified HVAC. |
| 8.9 | NORMAL OPERATING CONTROLS Comments: Inspected |
| 8.10 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected |
| Attic Insulation: Blown | Ventilation: Soffit Vents | Exhaust Fans: Fan only |
| Dryer Power Source: 220 Electric | Dryer Vent: Flexible Metal | Floor System Insulation: Loose fill (netted) |
| 9.0 | INSULATION IN ATTIC Comments: Inspected |
| 9.1 | INSULATION UNDER FLOOR SYSTEM Comments: Inspected |
| 9.2 | VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) Comments: Not Present |
| 9.3 | VENTILATION OF ATTIC AND FOUNDATION AREAS Comments: Inspected |
| 9.4 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Inspected |
| 9.5 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) Comments: Not Present |
| Dishwasher Brand: GENERAL ELECTRIC | Disposer Brand: IN SINK ERATOR | Exhaust/Range hood: NONE |
| Range/Oven: GENERAL ELECTRIC | Built in Microwave: HOTPOINT | Trash Compactors: NONE |
| Refrigerator: WHIRLPOOL |
| 10.0 | DISHWASHER Comments: Inspected |
| 10.1 | RANGES/OVENS/COOKTOPS Comments: Inspected |
| 10.2 | RANGE HOOD Comments: Not Present |
| 10.3 | TRASH COMPACTOR Comments: Not Present |
| 10.4 | FOOD WASTE DISPOSER Comments: Inspected |
| 10.5 | MICROWAVE COOKING EQUIPMENT Comments: Inspected |
![]() 1-2-3 Home Inspections
1418 Castleworks Ln. |
Customer |
Property Address |
| 1.0 | ROOF COVERINGS | |
| Repair or Replace | ||
|
The Roof shingles has been repaired at
the ridge. I am unable to determine if this repair will leak or fail.
A qualified contractor should inspect and repair as needed. |
||
|
Loose Granules could indicate that a
shingle roof covering is nearing the end of it's useful life. A
qualified contractor should repair or replace as needed. |
||
| 1.1 | FLASHINGS | |
| Repair or Replace | ||
|
Flashing may have failed above half
bath. There is evidence of a past or present leak on ceiling of
half bath. Siding has deteriorated and will continue to if not
repaired or replaced. A qualified contractor should inspect and
repair as necessary. |
||
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | |
| Inspected | ||
|
The plumbing vent pipe and exhaust fan
vent need resealing around the perimeter of pipe and boot
where boot flange has failed. |
||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |
| Repair or Replace | ||
|
The Composite board siding at the front
of home and rear of home is deteriorated. Further deterioration can
occur if not corrected. A qualified person should repair or
replace as needed. |
||
| 2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS | |
| Repair or Replace | ||
|
The floor joist(s) and decking on
the deck at the rear of home (Picture 1) and right
side (A/C platform) (Picture 2) appear to be water damaged
and has mold/mildew. Further deterioration can occur if not
repaired. I recommend monitor and repair if needed. |
||
| 2.5 | EAVES, SOFFITS AND FASCIAS | |
| Repair or Replace | ||
|
The wood fascia at eave on the front,
the right side (facing front) and left side (facing front) are
deteriorated. Further deterioration may occur if not repaired.
A qualified person should repair or replace as needed. |
||
|
The soffit panel at eave on the rear of
home is missing. Deterioration may occur if not corrected.
A qualified person should repair or replace as needed. |
||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | |
| Repair or Replace | ||
|
The Shower door missing knob hardware at
the Master bath. This is a small repair. A qualified person
should repair or replace as needed. |
||
|
The Entry door is missing a strike-plate
and dead-bolt plate on jamb at the garage. This is a small repair.
A qualified person should repair or replace as needed. |
||
|
The Sliding screen door is damaged
at the workshop. This is a maintenance issue and is for your
information. I recommend repair as desired. |
||
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) | |
| Repair or Replace | ||
|
One window difficult to operate at the
office. A repair may be needed. A qualified person
should repair or replace as needed. |
||
|
One window is damaged at handle or lock
hardware at the Dining Room. A repair may be needed. A qualified
person should repair or replace as needed. |
||
| 5.5 | ROOF STRUCTURE AND ATTIC | |
| Repair or Replace | ||
|
The roof sheathing is deteriorated under
soffit. Area still remains strong. It is not cost effective to replace
until next roof. A qualified contractor should repair as needed. |
||
| 6.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS | |
| Repair or Replace | ||
|
The plumbing waste line leaks at the Half
Bath sink. Repairs are needed. A qualified licensed plumber should
repair or correct as needed. |
||
|
The tub drain overflow is upside
down in the hall bath. Repairs are needed. A qualified person
should repair as necessary. |
||
| 6.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
| Repair or Replace | ||
|
The cold supply line has a corroded joint
at connection in the garage. A licensed plumber should
troubleshoot further to determine cause or remedy. |
||
|
The tub faucet and tub spout are loose in
wall and also need caulking at the hall bath. Repairs are needed.
A qualified licensed plumber should repair or correct as needed. |
||
|
The toilet stop-valve hose connection has
a possible leak or has leaked in the past at the hall bath. A qualified
licensed plumber should inspect and repair, if needed. A licensed
plumber should troubleshoot further to determine cause or remedy. |
||
|
The cold control tub faucet leaks at the
downstairs bath. Repairs are needed. A qualified licensed plumber
should repair or correct as needed. |
||
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | |
| Repair or Replace | ||
|
The main panel has one circuit breaker that appears to be popped out. A qualified electrician should repair or replace. |
||
| 8.8 | COOLING AND AIR HANDLER EQUIPMENT | |
| Repair or Replace | ||
|
The air handler is deteriorated. A more
thorough inspection by a qualified contractor is needed.
A licensed HVAC contractor should service or repair unit. |
||
|
The standard running temperature
difference between the return air and the cooled air should be
approximately 20 degrees
Fahrenheit. The second floor system had a return
air temperature of 73 degrees and a cooled air temperature
of 64 degrees. The first floor system had a return air
temperature of 78 degrees and a cooled air temperature of 60
degrees. The second floor system may need further inspection by a
qualified HVAC. |
||
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To 1-2-3 Home Inspections
This inspection was performed in accordance with and under the terms of a Pre-Inspection Agreement. The agreement was signed and agreed upon before the preparation of this report and a signed copy of the agreement is available upon request. An unsigned copy of the agreement may be attached to this report for your information or it may also be available on the home inspection company web site.
Home | Typical Inspection | Sample Report | Seller's Inspection | Pre-Inspection Agreement | Links